Error Codes and Recovery Procedures

Decimal

Error

Hex

Error

Description

Recovery Method

0

00H

Error code not set.

Power cycle the library.

Observe the LEDs on the back of the library

controller card. See

Interpreting Library LEDs

on page 130 to understand what the LEDs may

indicate.

1-8

01H -

08H

Failed library

controller self test.

01h through 08h are controller tests. These errors

are possible only on power-up.

Power cycle the library.

Observe the LEDs on the back of the library

controller card. See

Interpreting Library LEDs

on page 130 to understand what the LEDs may

indicate.

If failure persists, the library controller card

may be faulty.

9

09H

Failed translate motor

test.

Cannot translate the transport.

Check for a possible obstruction in the

transport pathway and remove it.

The umbilical cable may be faulty.

If the transport moves a little, but cannot fully

rotate around the assembly, a faulty motor is

indicated.

10

0AH

Failed vertical motor

test.

Occurs when trying to sense if the transport

assembly moves vertically. If the assembly does not

move:

Ensure that the motor leads are connected to

the vertical motor and the vertical lift board.

Check the umbilical cable under the translate

frame.