Table 46 – HP 20-Feb User Manual

Page 212

Advertising
background image

210 Library Error Codes

Appendix

Table 46

Error Codes and Recovery Procedures

Decimal

Error

Hex

Error

Description

Recovery Method

0

00H

Error code not set.

■

Power cycle the library.

■

Observe the LEDs on the back of the library

controller card. See

Interpreting Library LEDs

on page 130 to understand what the LEDs may

indicate.

1-8

01H -

08H

Failed library

controller self test.

01h through 08h are controller tests. These errors

are possible only on power-up.

■

Power cycle the library.

■

Observe the LEDs on the back of the library

controller card. See

Interpreting Library LEDs

on page 130 to understand what the LEDs may

indicate.

■

If failure persists, the library controller card

may be faulty.

9

09H

Failed translate motor

test.

Cannot translate the transport.

■

Check for a possible obstruction in the

transport pathway and remove it.

■

The umbilical cable may be faulty.

■

If the transport moves a little, but cannot fully

rotate around the assembly, a faulty motor is

indicated.

10

0AH

Failed vertical motor

test.

Occurs when trying to sense if the transport

assembly moves vertically. If the assembly does not

move:

■

Ensure that the motor leads are connected to

the vertical motor and the vertical lift board.

■

Check the umbilical cable under the translate

frame.

Advertising