HP 20-Feb User Manual

Page 17

Advertising
background image

Chapter 1

Choosing a Location 15

Cha
pter 1

Clearance

2/20, 4/40, and 6/60 series stand-alone configurations — located on or

below a table:

Back:

56 cm (22 in) for cooling and service.

Front:

86 cm (34 in) for operator access.

Sides:

56 cm (22 in) for removal of the external cover.

2/20, 4/40, and 6/60 series rackmounted configurations:

Back:

61 cm (24 in) minimum to allow adequate room for service

access.

Front:

86 cm (34 in) for operator access.

Sides:

56 cm (22 in) minimum

Height:

For ease of use and optimum safety, the top of the library

should be mounted approximately 120 cm (48 in) above the

floor.

8/80 and 10/100 series tape libraries

Back:

56 cm (22 in) minimum

Front:

191 cm (75 in) minimum

Sides:

5 cm (2 in) minimum

Floor rating

For 8/80 and 10/100 series tape libraries only.
A fully loaded library can weigh up to 325 kg (715 lbs). Each caster supports

up to 96 kg (213 lbs). To support the weight exerted on the floor by the casters,

the floor rating must meet or exceed 1,694 kg per square meter (347 lbs per

square foot).

Tip rating

For 8/80 and 10/100 series libraries only.
Do not tip the library more than 10°. Ensure that the location for the library has

a level surface.

Table 2

Location Criteria

Advertising