4. OPERATION

3) Program example 3

Program

Description

SPN (1000)
STC (20)
MOVI (1000)
OUTON (1)
TIM (20)
MOVI (500)
STOP

Speed (Motor speed)

1000 [r/min]

Acceleration/deceleration time constant

20 [ms]

Incremental move command

1000 [ 10

STM

m]

Program output 1 (OUT 1) is turned ON.

a)

Dwell command time

200 [ms]

b)

Incremental move command

500 [ 10

STM

m]

Program end

0r/min

ON

OFF

Forward
rotation

Servo motor
speed

Program
output1
(OUT1)

b) 200ms

a)

4) Program example 4

Program

Description

SPN (1000)
STC (20)
MOVI (1000)
TIM (20)
OUTON (1)
TIM (30)
MOVI (500)
STOP

Speed (Motor speed)

1000 [r/min]

Acceleration/deceleration time constant

20 [ms]

Incremental move command

1000 [ 10

STM

m]

Dwell command time

200 [ms]

a)

Program output 1 (OUT 1) is turned ON.

b)

Dwell command time

300 [ms]

c)

Incremental move command

500 [ 10

STM

m]

Program end

0r/min

ON

OFF

Forward
rotation

Servo motor
speed

Program
output1
(OUT1)

a) 200ms

c) 300ms

b)