Parameters – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 143

Advertising
background image

5 - 10

5. PARAMETERS

Class No. Symbol

Name and Function

Initial

value

Unit

Setting

range

B

asi

c p

ara

meters

18

*DMD Status display selection

Used to select the status display shown at power-on. (Refer to Section 7.2)

Status display on servo amplifier display
at power-on
00: Current position (initial value)
01: Command position
02: Command remaining distance
03: Program No.
04: Step No.
05: Cumulative feedback pulses
06: Servo motor speed
07: Droop pulses
08: Override voltage
09: Analog torque limit voltage
0A: Regenerative load ratio
0B: Effective load ratio
0C: Peak load ratio
0D: Instantaneous torque
0E: Within one-revolution position low
0F: Within one-revolution position high
10: ABS counter
11: Load inertia moment ratio
12: Bus voltage
Status display of MR-DP60 at power-on
00: Current position (initial value)
01: Command position
02: Command remaining distance
03: Program No.
04: Step No.
05: Cumulative feedback pulses
06: Servo motor speed
07: Droop pulses
08: Override voltage
09: Analog torque limit voltage
0A: Regenerative load ratio
0B: Effective load ratio
0C: Peak load ratio
0D: Instantaneous torque
0E: Within one-revolution position
0F: ABS counter
10: Load inertia moment ratio
11: Bus voltage

0000

Refer to

Name

and

function

column.