Parameters – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 157

Advertising
background image

5 - 24

5. PARAMETERS

(2) Contents of a setting

The servo amplifier is factory-set to output the servo motor speed to analog monitor 1 and the torque
to analog monitor 2. The setting can be changed as listed below by changing the parameter No.17
(analog monitor output) value:

Setting

Output item

Description

Setting

Output item

Description

0

Servo motor speed

8[V]

Max. speed

0 Max. speed

-8[V]

CCW direction

CW direction

6

Droop pulses
( 10V/128pulse)

10[V]

0 128[pulse]

-10[V]

CCW direction

CW direction

128[pulse]

1

Torque

8[V]

Max. torque

0 Max. torque

-8[V]

Driving in CW direction

Driving in CCW direction

7

Droop pulses
( 10V/2048pulse)

10[V]

0 2048[pulse]

-10[V]

CCW direction

CW direction

2048[pulse]

2

Servo motor speed

8[V]

Max. speed

0

Max. speed

CCW
direction

CW
direction

8

Droop pulses
( 10V/8192pulse)

10[V]

0 8192[pulse]

-10[V]

CCW direction

CW direction

8192[pulse]

3

Torque

8[V]

Max. torque

0

Max. torque

Driving in
CCW direction

Driving in
CW direction

9

Droop pulses
( 10V/32768pulse)

10[V]

0 32768[pulse]

-10[V]

CCW direction

CW direction

32768[pulse]

4

Current command

8[V]

Max. command

current

0 Max. command

current

-8[V]

CCW direction

CW direction

A

Droop pulses
( 10V/131072pulse)

10[V]

0

131072[pulse]

-10[V]

CCW direction

CW direction

131072[pulse]

5

Speed command

8[V]

Max. speed

0 Max. speed

-8[V]

CCW direction

CW direction

B

Bus voltage

8[V]

0

400[V]

Advertising