(3) Outside dimensions of the power return converters

[Unit : mm(in)]

AA

A

C

F

K

EE

BA

B

E

D

2- D hole

Rating plate

Front cover

Display
panel
window

Mounting foot (removable)

Mounting foot
movable

Cooling fan

Heat generation area outside mounting dimension

Power return

converter

A

AA

B

BA

C

D

E

EE

K

F

Approx.

weight [kg(Ib)]

FR-RC-15K

270

(10.630)

200

(7.874)

450

(17.717)

432

(17.008)

195

(7.677)

10

(0.394)

10

(0.394)

8

(0.315)

3.2

(0.126)

87

(3.425)

19

(41.888)

FR-RC-30K

340

(13.386)

270

(10.630)

600

(23.622)

582

(22.913)

195

(7.677)

10

(0.394)

10

(0.394)

8

(0.315)

3.2

(0.126)

90

(3.543)

31

(68.343)

(4) Mounting hole machining dimensions

When the power return converter is fitted to a totally enclosed type box, mount the heat generating
area of the converter outside the box to provide heat generation measures. At this time, the mounting
hole having the following dimensions is machined in the box.

[Unit : mm(in)]

Model

A

B

D

AA

BA

FR-RC-15K

260

(10.236)

412

(16.220)

10

(0.394)

200

(7.874)

432

(17.009)

FR-RC-30K

330

(12.992)

562

(22.126)

10

(0.394)

270

(10.630)

582

(22.913)

(AA)

(B

A

)

b

a

(2- D hole)

(Mounting hole)