1. FUNCTIONS AND CONFIGURATION

(3) MR-J2S-500CL

POINT

The servo amplifier is shown without the front cover. For removal of the

front cover, refer to Section 1.6.2.

MODE

UP

DOWN

SET

MODE

UP

DOWN

SET

Name/Application

Reference

Battery connector (CON1)
Used to connect the battery for absolute position data
backup.

Section4.5

Battery holder
Contains the battery for absolute position data backup. Section4.5
Display
The 5-digit, seven-segment LED shows the servo
status and alarm number.

Chapter7

Operation section
Used to perform status display, diagnostic, alarm and

parameter setting operations.

Chapter7

Used to set data.

Used to change the
display or data in each
mode.

Used to change the
mode.

I/O signal connector (CN1A)
Used to connect digital I/O signals.

Section3.3

Section3.3

I/O signal connector (CN1B)
Used to connect digital I/O signals.

Chapter6

Chapter15

Section14.1.4

Communication connector (CN3)
Used to connect a command device (RS-422/RS232C)
and output analog monitor data.

Encoder connector (CN2)
Connector for connection of the servo motor encoder.

Section3.3

Section14.1.4

Charge lamp
Lit to indicate that the main circuit is charged.
While this lamp is lit, do not reconnect the cables.

Control circuit terminal block (TE2)
Used to connect the control circuit power supply and
regenerative brake option.

Section3.7.2

Section14.1.4

Main circuit terminal block (TE1)
Used to connect the input power supply and servo
motor.

Section3.7.2

Section12.1

Section14.1.1

Name plate

Section1.3

Protective earth (PE) terminal ( )
Ground terminal.

Section3.10
Section12.1

Installation notch
(4 places)

Cooling fan