Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 82

Advertising
background image

3 - 35

3. SIGNALS AND WIRING

3.11 Servo amplifier terminal block (TE2) wiring method

1) Termination of the cables

Solid wire: After the sheath has been stripped, the cable can be used as it is. (Cable size: 0.2 to

2.5mm

2

)

Approx. 10mm
(0.39inch)

Twisted wire: Use the cable after stripping the sheath and twisting the core. At this time, take

care to avoid a short caused by the loose wires of the core and the adjacent pole.
Do not solder the core as it may cause a contact fault. (Cable size: 0.2 to 2.5mm

2

)

Alternatively, a bar terminal may be used to put the wires together.

Cable size

Bar terminal type

[mm

2

]

AWG

For 1 cable

For 2 cables

Crimping tool

Maker

BT1.25-9-1

NH1

NICHIFU

1.25

16

TUB-1.25

YHT-2210

JST

AI-TWIN2 1.5-8BK

1.5

16

AI1.5-8BK

AI-TWIN2 1.5-12BK

CRIMPFOX-UD6

Phoenix Contact

BT2-9-1

NH1

NICHIFU

2

14

TUB-2

YHT-2210

JST

2.5

14

AI2.5-8BU
AI2.5-8BK-1000

AI-TWIN2 2.5-10BU
AI-TWIN2 2.5-13BU

CRIMPFOX-UD6

Phoenix Contact

2) Connection

Insert the core of the cable into the opening and tighten the screw with a flat-blade screwdriver
so that the cable does not come off. (Tightening torque: 0.3 to 0.4N m (2.7 to 3.5Ib in)) Before
inserting the cable into the opening, make sure that the screw of the terminal is fully loose.
When using a cable of 1.5mm

2

or less, two cables may be inserted into one opening.

To loosen.

To tighten.

Opening

Control circuit terminal block

Cable

Flat-blade screwdriver

Tip thickness 0.4 to 0.6mm (0.016 to 0.024in.)

Overall width 2.5 to 3.5mm (0.098 to 0.138in.)