Troubleshooting – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 233

Advertising
background image

11 - 6

11. TROUBLESHOOTING

Display

Name

Definition

Cause

Action

1. Servo amplifier fault caused the

parameter setting to be rewritten.

Change the servo amplifier.

2. Regenerative brake option not used

with servo amplifier was selected in
parameter No.0.

Set parameter No.0 correctly.

3. Value outside setting range has

been set in some parameter.

Set the parameter correctly.

4. Value outside setting range has

been set in electronic gear.

Set parameters No. 4, 5 correctly.

5. Opposite sign has been set in

software limit increasing side
(parameters No. 46, 47). Similarly,
opposite sign has been set in
software limit decreasing side
(parameters No. 48, 49).

Set parameters No. 46 to 49 correctly.

6. Opposite sign has been set in

position range output address
increasing side (parameters No. 50,
51). Similarly, opposite sign has
been set in position range output
address decreasing side (parameters
No. 52, 53).

Set parameters No. 50 to 53 correctly.

AL.37 Parameter

error

Parameter setting is
wrong.

7. The number of write times to EEP-

ROM exceeded 100,000 due to
parameter write, program write, etc.

Change the servo amplifier.

1. Servo amplifier fault caused the

program data to be rewritten.

Change the servo amplifier.

2. Command argument is out of the

setting range.

Programming correctly.

AL.39 Program error Program data is

abnormal

3. The number of write times to EEP-

ROM exceeded 100,000 due to
parameter write, program write, etc.

Change the servo amplifier.

1. Servo amplifier faulty.

Change the servo amplifier.

2. The power supply was turned on

and off continuously by overloaded
status.

The drive method is reviewed.

AL.45 Main circuit

device overheat

Main circuit device
overheat

3. Air cooling fan of servo amplifier

stops.

1. Exchange the cooling fan or the servo

amplifier.

2. Reduce ambient temperature.

1. Ambient temperature of servo motor

is over 40 .

Review environment so that ambient
temperature is 0 to 40 .

2. Servo motor is overloaded.

1. Reduce load.
2. Review operation pattern.
3. Use servo motor that provides larger

output.

AL.46 Servo motor

overheat

Servo motor
temperature rise
actuated the
thermal protector.

3. Thermal protector in encoder is

faulty.

Change servo motor.

Advertising