Parameters – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 149

Advertising
background image

5 - 16

5. PARAMETERS

Class No. Symbol

Name and Function

Initial

value

Unit

Setting

range

Ex

pan

si

on

par

ame

te

rs

2

59

OPA

Function selection A
Used to select the alarm code.

Setting of alarm code output

Connector pins

Set

value

CN1B-19

CN1A-18

CN1A-19

0
1

88888
AL.12
AL.13
AL.15
AL.17

AL.39

AL.8E

AL.30

AL.45

AL.50
AL.51
AL.24
AL.32
AL.31
AL.35
AL.52

AL.16

AL.20

Name

Watchdog
Memory error 1
Clock error
Memory error 2
Board error 2

Program error

Serial communication error
Regenerative error

Main circuit device overheat

Overload 1
Overload 2
Main circuit
Overcurrent
Overspeed
Command pulse frequency error
Error excessive

Encoder error 1

Encoder error 2

Alarm

display

(Note) Alarm code

CN1B
pin 19

0

0

0

0

1

CN1A
pin 18

0

0

1

1

0

1

CN1A
pin 19

1

1

0

1

0

1

0

Note: 0:OFF

1:ON

AL.19 Memory error 3
AL.37 Parameter error

AL.33 Overvoltage

AL.46 Servo motor overheat

AL.10 Undervoltage

1

0

0

AL.1A

AL.25

Motor combination error

Absolute position erase

Alarm code is output at alarm occurrence.

Signals assigned to corresponding pins are output.

CW direction

CCW direction

Setting

0

Rotation direction in which torque limit is made valid

1
2

0

0

AL.63
AL.64

Home position return incomplete
Home position setting error

AL.8A

Serial communication time-out error

0000

Refer to

Name

and

function

column.

Advertising