2 manual pulse generator operation, Operation – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 112

Advertising
background image

4 - 29

4. OPERATION

4.3.2 Manual pulse generator operation

(1) Setting

Set the input signal and parameters as follows according to the purpose of use. In this case, the
program No. selection 1 to 4 (DI0 to DI3) are invalid:

Item

Setting method

Description

Manual operation mode selection

Automatic/manual selection (MD0)

MD0 is switched off.

Manual pulse generator
multiplication

Parameter No.1

Set the multiplication ratio of servo
motor rotation to the pulses generated
by the manual pulse generator.
For more information, refer to (3) in this
section.

Servo motor rotation direction

Parameter No.1

Refer to (2) in this section.

Jog speed

Parameter No.13

Set the speed of the servo motor.

Acceleration/deceleration time
constant

Parameter No.40

Use the acceleration/deceleration time
constants.

(2) Servo motor rotation direction

Servo motor rotation direction

Parameter No. 1 setting

Manual pulse generator: forward rotation

Manual pulse generator: reverse rotation

0

CCW rotation

CW rotation

1

CW rotation

CCW rotation

Forward rotation

CCW

CW

(3) Manual pulse generator multiplication

(a) Using the parameter for setting

Use parameter No.1 to set the multiplication ratio of the servo motor rotation to the manual pulse
generator rotation.

Parameter No. 1 setting

Multiplication ratio of servo motor rotation to manual

pulse generator rotation

Moving distance

0

1 time

1[ m]

1

10 times

10[ m]

2

100 times

100[ m]

Advertising