background image

1 - 21

1. FUNCTIONS AND CONFIGURATION

(b) For 1-phase 100V to 120VAC

1-phase 100V
to 120VAC
power supply

No-fuse breaker
(NFB) or fuse

Magnetic
contactor
(MC)

To CN2

To CN3

To CN1B

To CN1A

L

21

L

11

Protective earth (PE) terminal

Servo motor

Personal
computer

U

V

W

Servo configuration
software
MRZJW3-SETUP151E

Servo amplifier

Regenerative brake
option

D

P

C

CHARGE

Control circuit terminal block

(Note)
Encoder cable

Note: The HC-SFS, HC-RFS, HC-UFS 2000 r/min series have cannon connectors.

(Note)
Power supply lead

L

1

L

2

Power
factor
improving
reactor
(FR-BAL)

Options and auxiliary equipment

No-fuse breaker

Magnetic contactor

Servo configuration software

Regenerative brake option

Reference

Section 14.2.2

Section 14.2.2

Chapter 6

Section 14.1.1

Options and auxiliary equipment

Reference

Cables

Manual pulse generator

External digital display

Section 14.2.1

Section 14.1.8

Section 14.1.7

Power factor improving reactor Section 14.2.3

Junction terminal block

Manual pulse generator

External digital display

Command device