3. SIGNALS AND WIRING

Device name

Devices

symbol

Connector

pin No.

Functions/Applications

Select the program number from among those combined by DI0, DI1, DI2 and DI3
to start operation on the leading edge of ST1 in the program operation mode.

Program No. selection 1

DI0

CN1B-5

Input signal (Note)

DI3

DI2

DI1

DI0

Program No.

Program No. selection 2

DI1

CN1B-14

0

0

0

0

1

0

0

0

1

2

Program No. selection 3

DI2

0

0

1

0

3

0

0

1

1

4

0

1

0

0

5

0

1

0

1

6

0

1

1

0

7

0

1

1

1

8

1

0

0

0

9

1

0

0

1

10

1

0

1

0

11

1

0

1

1

12

1

1

0

0

13

1

1

0

1

14

1

1

1

0

15

1

1

1

1

16

Program No. selection 4

DI3

Note. 0: OFF

1: ON

Override selection

OVR

Turn OVR on to make override (VC) valid.

External torque limit
selection

TL

Turn TL on to make analog torque limit (TLA) valid.
For details, refer to Section 3.4.4.

Internal torque limit
selection

TL2

Turn TL2 off to make parameter No.28 (Internal torque limit 1) valid, or turn it on
to make parameter No.29 (Internal torque limit 2) valid.
For detailes, refer to Section 3.4.4.

Proportion control

PC

Turn PC on to bring the speed amplifier from the proportional integral type to the
proportional type.
If the servo motor at a stop is rotated even one pulse due to any external factor, it

generates torque to compensate for a position shift. In such a case where the axis

will be locked mechanically after Movement complete (PED) has turned off, turning
Proportion control (PC) on as soon as Movement complete (PED) turns off can

suppress unnecessary torque that attempts to compensate for a position shift.
When the shaft is to be locked for a long time, switch on the proportion control (PC)
and External torque limit selection (TL) at the same time to make the torque less
than the rated by the analog torque limit (TLA).