(1) Status display (Command [0][1])

Command

Data No.

Description

Display item

Frame length

[0][1]

[8][0]

Current position

12

[0][1]

[8][1]

Command position

12

[0][1]

[8][2]

Command remaining distance

12

[0][1]

[8][3]

Program No.

12

[0][1]

[8][4]

Step No.

12

[0][1]

[8][5]

Cumulative feedback pulses

12

[0][1]

[8][6]

Servo motor speed

12

[0][1]

[8][7]

Droop pulses

12

[0][1]

[8][8]

Override

12

[0][1]

[8][9]

Torque limit voltage

12

[0][1]

[8][A]

Regenerative load ratio

12

[0][1]

[8][B]

Effective load ratio

12

[0][1]

[8][C]

Peak load ratio

12

[0][1]

[8][D]

Instantaneous torque

12

[0][1]

[8][E]

Within one-revolution position

12

[0][1]

[8][F]

ABS counter

12

[0][1]

[9][0]

Load inertia moment ratio

12

[0][1]

[9][1]

Status display data value and
processing information

Bus voltage

12

(2) Parameter (Command [0][5])

Command

Data No.

Description

Frame length

[0][5]

[0][0] to

[5][A]

Current value of each parameter
The decimal equivalent of the data No. value (hexadecimal) corresponds
to the parameter number.

8

(3) External I/O signals (Command [1][2])

Command

Data No.

Description

Frame length

[1][2]

[0][0]

Input device statuses

8

[1][2]

[4][0]

External input pin statuses

8

[1][2]

[6][0]

Statuses of input devices switched on through communication

8

[1][2]

[8][0]

Output device statuses

8

[1][2]

[C][0]

External output pin statuses

8

Advertising