Communication functions – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 309

Advertising
background image

15 - 12

15. COMMUNICATION FUNCTIONS

(4) Alarm history (Command [3][3])

Command

Data No.

Description

Alarm occurrence sequence

Frame length

[3][3]

[1][0]

Most recent alarm

4

[3][3]

[1][1]

First alarm in past

4

[3][3]

[1][2]

Second alarm in past

4

[3][3]

[1][3]

Third alarm in past

4

[3][3]

[1][4]

Fourth alarm in past

4

[3][3]

[1][5]

Alarm number in alarm history

Fifth alarm in past

4

[3][3]

[2][0]

Most recent alarm

8

[3][3]

[2][1]

First alarm in past

8

[3][3]

[2][2]

Second alarm in past

8

[3][3]

[2][3]

Third alarm in past

8

[3][3]

[2][4]

Fourth alarm in past

8

[3][3]

[2][5]

Alarm occurrence time in alarm
history

Fifth alarm in past

8

(5) Current alarm (Command [0][2] [3][5])

Command

Data No.

Description

Frame length

[0][2]

[0][0]

Current alarm number

4

Command

Data No.

Description

Status display item

Frame length

[3][5]

[8][0]

Current position

12

[3][5]

[8][1]

Command position

12

[3][5]

[8][2]

Command remaining distance

12

[3][5]

[8][3]

Program No.

12

[3][5]

[8][4]

Step No.

12

[3][5]

[8][5]

Cumulative feedback pulses

12

[3][5]

[8][6]

Servo motor speed

12

[3][5]

[8][7]

Droop pulses

12

[3][5]

[8][8]

Override

12

[3][5]

[8][9]

Torque limit voltage

12

[3][5]

[8][A]

Regenerative load ratio

12

[3][5]

[8][B]

Effective load ratio

12

[3][5]

[8][C]

Peak load ratio

12

[3][5]

[8][D]

Instantaneous torque

12

[3][5]

[8][E]

Within one-revolution position

12

[3][5]

[8][F]

ABS counter

12

[3][5]

[9][0]

Load inertia moment ratio

12

[3][5]

[9][1]

Status display data value and
processing information at alarm
occurrence

Bus voltage

12

Advertising