5 - 5

5. PARAMETERS

(2) Detail list

Class No. Symbol

Name and Function

Initial

value

Unit

Setting

range

B

asi

c p

ara

meters

0

*STY

Command system, regenerative brake option selection
Used to select the command system and regenerative brake option.

Selection of command system
(Refer to Section 4.2)
0: Absolute value command system
1: Incremental value command system

0

Selection of regenerative brake option
(Refer to Section 14.1.1)
0: Not used
(The built-in regenerative brake resistor is used.)
1: Spare (do not set)
2:MR-RB032
3:MR-RB12
4:MR-RB32
5:MR-RB30
6:MR-RB50
8:MR-RB31
9:MR-RB51
If the regenerative brake option selected is not for
use with the servo amplifier, parameter error
occurs.

Program edit
0: Valid
1: Invalid

0000

Refer to