2 diagnosis mode list, Display and operation – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 189

Advertising
background image

7 - 6

7. DISPLAY AND OPERATION

7.3.2 Diagnosis mode list

Name

Display

Description

Not ready.
Indicates that the servo amplifier is being initialized or an alarm
has occurred.

Sequence

Ready.
Indicates that the servo was switched on after completion of
initialization and the servo amplifier is ready to operate.

External I/O signal
display

Refer to section 7.6.

Indicates the ON-OFF states of the external I/O signals.
The upper segments correspond to the input signals and the
lower segments to the output signals.

Lit: ON
Extinguished: OFF

The I/O signals can be changed using the servo configuration
software.

Output signal (DO)
forced output

The digital output signal can be forced on/off. (Refer to Section
7.7)

Jog feed

Jog operation can be performed when there is no command from
the external command device. (Refer to Section 7.8.2)

Positioning
operation

The servo configuration software (MRZJW3-SETUP151E) is
required for positioning operation. This operation cannot be
performed from the operation section of the servo amplifier.
Positioning operation can be performed once when there is no
command from the external command device.

Motorless
operation

Without connection of the servo motor, the servo amplifier
provides output signals and displays the status as if the servo
motor is running actually in response to the external input
signal. (Refer to Section 7.9.4)

Test
operation
mode

Machine
analyzer
operation

Merely connecting the servo amplifier allows the resonance point
of the mechanical system to be measured.
The servo configuration software (MRZJW3-SETUP151E or later)
is required for machine analyzer operation.

Software version Low

Indicates the version of the software.

Software version High

Indicates the system number of the software.

For manufacturer
setting

Maker setting screen. Do not perform operation on this screen.

Advertising