11 - 9

11. TROUBLESHOOTING

11.2.3 Remedies for warnings

If AL.E6 occurs, the servo off status is established. If any other warning occurs, operation can be
continued but an alarm may take place or proper operation may not be performed. Use the optional servo

configuration software to refer to the cause of warning.

Display

Name

Definition

Cause

Action

1. Battery cable is open.

Repair cable or changed.

AL.92 Open battery

cable warning

Absolute position
detection system battery
voltage is low.

2. Battery voltage dropped to 2.8V or less. Change battery.

AL.97 Program

operation disable

Program was started in a
program operation
disable status.

After a program change, the program was
started without the servo amplifier being
powered off/on.

Power off/on the servo amplifier.

1. Software limit was set within actual

operation range.

Set parameter No. 48 to 51
correctly.

2. Program of position data in excess of

software limit was executed.

Set program correctly.

AL.98 Software limit

warning

Software limit set in
parameter is reached.

3. Software limit was reached during JOG

operation or manual pulse generator
operation.

Perform operation within
software limit range.

AL.9F Battery warning Voltage of battery for

absolute position
detection system reduced.

Battery voltage fell to 3.2V or less.

Change the battery.

AL.E0 Excessive

regenerative
warning

There is a possibility that
regenerative power may
exceed permissible
regenerative power of
built-in regenerative
brake resistor or
regenerative brake
option.

Regenerative power increased to 85% or
more of permissible regenerative power of
built-in regenerative brake resistor or
regenerative brake option.

Checking method

Call the status display and check
regenerative load ratio.

1. Reduce frequency of

positioning.

2. Change regenerative brake

option for the one with larger
capacity.

3. Reduce load.

AL.E1 Overload

warning

There is a possibility that
overload alarm 1 or 2
may occur.

Load increased to 85% or more of overload
alarm 1 or 2 occurrence level.

Cause, checking method

Refer to AL.50,51.

Refer to AL.50, AL.51.

1. Noise entered the encoder.

Take noise suppression
measures.

AL.E3 Absolute position

counter warning

Absolute position encoder
pulses faulty.

2. Encoder faulty.

Change servo motor.

AL.E6 Servo forced stop

warning

EMG-SG are open.

External forced stop was made valid.
(EMG-SG opened.)

Ensure safety and deactivate
forced stop.

AL.E9 Main circuit off

warning

Servo was switched on
with main circuit power
off.

Switch on main circuit power.