background image

4 - 36

4. OPERATION

4.4.4 Data setting type home position return

Data setting type home position return is used when it is desired to determine any position as a home
position. JOG operation, manual pulse generator operation or like can be used for movement.

(1) Signals, parameters

Set the input signals and parameters as follows:

Item

Device/Parameter used

Description

Manual home position return mode
selection

Automatic/manual selection
(MD0)

MD0 is switched on.

Data setting type home position return Parameter No.8

2 : Data setting type home position

return is selected.

Home position return position data

Parameter No.42

Used to set the current position on completion
of home position return.

Program

Select the program including the
"ZRT" command that executes a
home position return.

(2) Timing chart

The following shows the timing chart that starts after selection of the program including the "ZRT"
command.

Movement complete (PED)

Home position

return completion

(ZP)

Forward rotation

start (ST1)

ON
OFF

ON
OFF

ON
OFF

3ms or less

Home position address
Parameter No. 42

ON
OFF

Automatic/manual

selection

(MD0)

5ms or more

Servo motor speed

Forward
rotation
0 r/min

The address on completion of home position return is the value automatically set in parameter No.42
(home position return position data).