5 - 1

5. PARAMETERS

5. PARAMETERS

CAUTION

Never adjust or change the parameter values extremely as it will make operation

instable.

5.1 Parameter list

5.1.1 Parameter write inhibit

POINT

Set "000E" when using the Servo Configuration Software to make device
setting.

After setting the parameter No.19 value, switch power off, then on to
make that setting valid.

In the servo amplifier, its parameters are classified into the basic parameters (No.0 to 19), expansion
parameters 1 (No.20 to 53), expansion parameters 2 (No.54 to 77) and special parameters (No.78 to 90)
according to their safety aspects and frequencies of use. In the factory setting condition, the customer can
change the basic parameter values but cannot change the expansion parameter 1,2 values and special
parameter values. When fine adjustment, e.g. gain adjustment, is required, change the parameter No.19
setting to make the expansion parameters write-enabled.
The following table lists the parameters whose values are made valid for reference/write by setting
parameter No. 19. Operation can be performed for the parameters marked .

Parameter No.19

setting

Operation

Basic parameters

No.0 to No.19

Expansion parameters 1

No.20 to No.53

Expansion parameters 2

No.54 to No.77

special parameters (No.78 to 90)

Reference

0000

(initial value)

Write

Reference

No.19 only

000A

Write

No.19 only

Reference

000B

Write

Reference

000C

Write

Reference

000E

Write