3 parameters, Special adjustment functions – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 221

Advertising
background image

9 - 6

9. SPECIAL ADJUSTMENT FUNCTIONS

9.5.3 Parameters

When using the gain changing function, always set " 4 " in parameter No.3 (auto tuning) to choose
the manual mode of the gain adjustment modes. The gain changing function cannot be used in the auto
tuning mode.

Parameter

No.

Abbrev-

iation

Name

Unit

Description

7

PG1

Position control gain 1

rad/s

36

VG1

Speed control gain 1

rad/s

Position and speed gains of a model used to set the response
level to a command. Always valid.

34

GD2

Ratio of load inertia moment to
servo motor inertia moment

0.1

times

35

PG2

Position control gain 2

rad/s

37

VG2

Speed control gain 2

rad/s

38

VIC

Speed integral compensation

ms

Control parameters before changing

64

GD2B

Ratio of load inertia moment to
servo motor inertia moment 2

0.1

times

Used to set the ratio of load inertia moment to servo motor
inertia moment after changing.

65

PG2B

Position control gain 2 changing
ratio

%

Used to set the ratio (%) of the after-changing position
control gain 2 to position control gain 2.

66

VG2B

Speed control gain 2 changing
ratio

%

Used to set the ratio (%) of the after-changing speed control
gain 2 to speed control gain 2.

67

VICB

Speed integral compensation
changing ratio

%

Used to set the ratio (%) of the after-changing speed integral
compensation to speed integral compensation.

68

CDP

Gain changing selection

Used to select the changing condition.

69

CDS

Gain changing condition

kpps

pulse
r/min

Used to set the changing condition values.

70

CDT

Gain changing time constant

ms

You can set the filter time constant for a gain change at
changing.

Advertising