15. COMMUNICATION FUNCTIONS

15.12.6 Disable/enable of I/O devices (DIO)

Inputs can be disabled independently of the I/O devices ON/OFF. When inputs are disabled, the input
signals (devices) are recognized as follows. Among the input devices, EMG, LSP and LSN cannot be
disabled.

Signal

Status

Input devices (DI)

OFF

External analog input signals

0V

Pulse train inputs

None

(1) Disabling/enabling the input devices (DI), external analog input signals and pulse train inputs with

the exception of EMG, LSP and LSN.
Transmit the following communication commands:
(a) Disable

Command

Data No.

Data

[9][0]

[0][0]

1EA5

(b) Enable

Command

Data No.

Data

[9][0]

[1][0]

1EA5

(2) Disabling/enabling the output devices (DO)

Transmit the following communication commands:
(a) Disable

Command

Data No.

Data

[9][0]

[0][3]

1EA5

(b) Enable

Command

Data No.

Data

[9][0]

[1][3]

1EA5