2 movement complete, Signals and wiring – MITSUBISHI ELECTRIC MR-J2S- CL User Manual

Page 61

Advertising
background image

3 - 14

3. SIGNALS AND WIRING

3.4.2 Movement complete

POINT

If servo-on occurs after a stop made by servo-off, alarm occurrence or
Forced stop (EMG) ON during automatic operation, Movement complete
(PED), turn on. To make a start again, confirm the program No. being
specified, and turn on Forward rotation start (ST1).

The following timing charts show the output timing relationships between the position command
generated in the servo amplifier and the Movement complete (PED). This timing can be changed using
parameter No. 6 (Movement complete output range). Turn PED on to bring in the servo-on status.

Forward rotation start (ST1)

or reverse rotation start (ST2)

Position command and

servo motor speed

3ms or less

Movement complete range

Servo motor speed

Position command

OFF

ON

OFF

ON

Movement complete (PED)

When parameter No. 6 is small

Forward rotation start (ST1)

or reverse rotation start (ST2)

Position command and

servo motor speed

Movement complete (PED)

3ms or less

Movement complete range

Servo motor speed

Position command

OFF

ON

OFF

ON

When parameter No. 6 is large