4 - 2

4. OPERATION

4.1.2 Startup

WARNING

Do not operate the switches with wet hands. You may get an electric shock.

CAUTION

Before starting operation, check the parameters. Some machines may perform

unexpected operation.

During power-on or soon after power-off, do not touch the servo amplifier heat

sink, regenerative brake resistor, servo motor, etc. as they may be at high

temperatures. You may get burnt.

Connect the servo motor with a machine after confirming that the servo motor operates properly alone.
For startup reference, a single machine structure will be described. Refer to this section and start up the
machine safely.

(1) Machine conditions

Program No. 2

Servo motor

HC-MFS131072pulse/rev

Servo motor
speed

Ballscrew
P

B

10mm(0.39inch)

Reduction ratio

1/n 1/2

Servo amplifier

Regenerative
brake option
MR-RB032

Ta

Tb

0r/min

V

Position data (P) 200mm(787.40inch)
Speed (V) 2500r/min
Acceleration time constant (Ta) 200ms
Deceleration time constant (Tb) 300ms

P

P

B

1) Absolute position detection system used
2) Command resolution: 10 m
3) Command system: Absolute value command system
4) Electronic gear calculation

CMX(pulse)

CDV( m)

131072

131072

10

131072

5000

32768

1250

1

n P

B

1000

1000

1
2

........................................................(4.1)

CMX 32768
CDV 1250

5) External input signals are used by the program selection, forward rotation start (ST1), servo-on

(SON) and other commands.

6) Program No.2 is used to execute program operation once.