SATO HT200e User Manual

Page 115

Advertising
background image

SECTION 6: ON LINE

Page 6-10

SATO HT200e

4.

Preset data: It can be sent with DATA STORE/RECALL in data maintenance mode.
Setting for preset data:
Data in the same format as fixed data of the print parameter shall be set. However, if C/D is
present in the barcode field, calculate C/D and set. When format is registered, record preset.

For one data to be transmitted, SOH + 9 as header and EOT as trailer should be put for all
items.

 

(Up to 29 fields)

Note: Parenthesis shows the number of byte for each term.

SOH

9

STX

Preset No. (4)

Format No. (2)

Preset data (32)

Preset data (32)

Preset data (32)

ETX

EOT

Advertising