SECTION 6: ON LINE

SATO HT200e

Page 6-13

3.

Signal for incoming and outgoing:

4.

Protocol
1) Ready / Busy

This communication protocol receives print data only through the control of hardware sig-
nal
without software procedure.
ER signal will be used for the control of Ready/Busy.
“High”

→ Ready

“Low”

→ Busy

Receiving data can not assured in the following conditions when:
a)Printer is in off-line mode.
b)Printer error is occurred.

5.

Code for control:

Pin

No.

Signal

Direction

Description

1

FG

Frame ground

2

SD

Out

Data sent from a printer to a host.

3

RD

In

Data sent from a host to a printer

4

RS

Out

It consistently remains high level.

5

CS

Un-use

6

DR

In

It should consistently retain high level.

7

SG

Signal ground

9

ER

Out

“High” shows a condition that a printer can receive.
“Low” is a general mode.

Name

Code

Action

Note

STX

02H

Start of text data

ETX

03H

End of text data

ESC

1BH

Command

EOT

04H

End of communication

It can be used when font is
registered.

SOH

01H

Command for specifying medium