SECTION 4

: FREE MODE

Page 4-2

SATO HT200e

FIELD PARAMETER

Component of field parameter

Field designation

Print setting (Font type)

Note 1: Field Designation (Normal) shall not usually limit the entry for price and calendar and process data.
Note 2: Format 00 can be used to specify whether EAN guard bar is available or not.

For the following pages, parameter in the designation of each field will be described.

Item

Field designation

Print setting

Designation for input

check

Copy setting

No. of digits

1 to 2

3 to 15

16 to 21

22 to 46

Field designation

Font type

1st digit

2nd digit

3rd digit

1: Normal

0: Normal

0: X1 1: X2 2: X3
4: OCR-B

1: Table data
2: Sequential number

2: Price

0: Normal

0: X1 1: X2 2: X3
5: Character for price

1: POP

0: POP1

  1: POP2

2: POP3

3: Calendar

0: Date

1: X2 2: X3

1: Time

7: Bar code

0: Human readable

information (HRI) is
NOT available.

0: NW-7

1: CODE39

2: INT2of5

3: EAN13

4: EAN8

5: UPC-E

6: CODE128 (C Set)
7: CODE128 (B Set)

1: Human readable

information (HRI) is
available.

0: Functional field 0: Quantity

Field parameter allows a printer to set object, location, and
identity.

The format consists of a collection of each print item called
a field.

Format 1

Price

(Field 3)

Bar code

(Field 2)

Product name

(Field 1)