Configuring Access Point Security

6-17

5.

Configure the

WEP 64 Settings

or

WEP 128 Settings

field as required to define the Pass

Key used to generate the WEP keys. These keys must be the same between the AP-5131 and
its MU to encrypt packets between the two devices.

Default (hexadecimal) keys for WEP 64 include:

Pass Key

Specify a 4 to 32 character pass key and click the

Generate

button.

The pass key can be any alphanumeric string. The

AP-5131

, other

proprietary routers and Symbol MUs use the algorithm to convert
an ASCII string to the same hexadecimal number. MUs without
Symbol adapters need to use WEP keys manually configured as
hexadecimal numbers.

Keys #1-4

Use the

Key #1-4

areas to specify key numbers. The key can be

either a hexadecimal or ASCII depending on which option is
selected from the drop-down menu. For WEP 64 (40-bit key), the
keys are 10 hexadecimal characters in length or 5 ASCII characters.
For WEP 128 (104-bit key), the keys are 26 hexadecimal characters
in length or 13 ASCII characters. Select one of these keys for
activation by clicking its radio button.