3 power injector led indicators, Power injector led indicators -10 – Symbol Technologies AP-5131 User Manual

Page 50

Advertising
background image

AP-5131 Access Point Product Reference Guide

2-10

Ensure the cable length from the Ethernet source (host) to the power injector and AP-5131
does not exceed 100 meters (333 ft.)

The power injector has no On/Off power switch. The power injector receives power and is
ready for AP-5131 device connection and operation as soon as AC power is applied.

2.6.1.3 Power Injector LED Indicators

The power injector demonstrates the following LED behavior under normal and/or problematic
operating conditions:

For more information and device specifications for the Symbol power injector, refer to the Power
Injector Quick Install Guide
(Part No. 72-70762-01) available from the Symbol Web site or the AP-5131
Software and documentation CDROM.

LED AC

(Main)

Port

Green (Steady) Power injector is receiving power from AC

outlet.

Indicates a device is connected to the
power injector’s outgoing Data & Power
cable.

Green (Blinking) Output voltage source is out of range.

The power injector is overloaded or has a
short circuit.