Sun Microsystems Sun Fire X4100 User Manual

Page 119

Advertising
background image

Chapter 3

Maintaining the Sun Fire X4100 Server

3-59

FIGURE 3-56

Motherboard Securing Screw and Bus-Bar Nut Locations

16. Use the lifting handle to raise the forward edge of the board until it has cleared

the bus bar studs.

Caution –

When lifting the board, use caution to avoid damaging the light pipes

and connectors on the rear edge of the motherboard.

17. Slide the board toward the front of the chassis until the connectors and light pipes

are clear of the chassis back panel. Then raise the motherboard and remove it
from the chassis.

Caution –

When reinstalling the CPUs and heatsinks to the motherboard, follow the

instructions in

Section 3.4.2, “Replacing a CPU and Heatsink” on page 3-10

.

Installation is the reverse of this procedure.

Note –

If you removed the HDDs from the server, when you replace the HDDs to

their bays, you must return each HDD to the bay from which it was removed. If the
HDDs were previously configured as a mirrored RAID 1 array, an automatic
resynchronization is invoked with no need to reconfigure the RAID parameters. Any
hot-spares are automatically reconfigured as hot-spares in the configuration.

The bus-bar
nuts are located
here (not
visible under the
cable in this
view)

Advertising