background image

4-20

Sun Fire X4100 and Sun Fire X4200 Servers Service Manual • June 2006

4.4.4

Installing a DVD-ROM Drive Upgrade Kit

Follow these steps to install a DVD-ROM upgrade kit to a system that previously
did not have a DVD-ROM drive.

If you are removing and replacing an existing DVD-ROM drive, see

Section 4.4.3,

“Replacing the DVD-ROM Drive” on page 4-17

.

Note –

This component is a FRU and should be replaced only by qualified service

technicians. Contact your Sun Service representative for assistance.

TABLE 4-3

lists the qualified part numbers for this component. These part numbers

are subject to change over time. For the most up-to-date list of replaceable
components, product updates, and downloads, see the following URL:

http://www.sun.com/servers/entry/x4100/downloads.jsp

1. Power off the server as described in

Section 4.2.1, “Powering Off the Server” on

page 4-2

.

2. If the server is in a rack, slide it far enough from the rack so that you can remove

the main cover and front cover. If you cannot safely view and access the
component, remove the server from the rack.

3. Remove the main cover as described in

Section 4.2.2, “Removing the Main Cover”

on page 4-3

.

4. Remove the front bezel as described in

Section 4.2.3, “Removing the Front Bezel”

on page 4-4

.

Note –

Always unfasten the bezel’s securing screw before removing the bezel.

5. Remove the front cover as described in

Section 4.2.4, “Removing the Front Cover”

on page 4-5

.

TABLE 4-4

Sun Fire X4200 Supported DVD-ROM Upgrade Kit Part Numbers

Component

Part Number

DVD-ROM Upgrade Kit

X8030A-Z