Chapter 3

Maintaining the Sun Fire X4100 Server

3-61

The system designation and the speeds of the two PCI slots are shown in

FIGURE 3-57

.

The slots for the PCI cards are detected by the system BIOS during bootup in the
order described in

Section 2.3.2.1, “PCI Card Slot Booting Priority” on page 2-5

.

Note –

Before you install a card, consult the manufacturer’s documentation for

system requirements and configuration information for your specific PCI card.

FIGURE 3-57

Sun Fire X4100 Designation and Speeds of PCI Slots

5. Remove any existing PCI card from the slot, or go to

Step 6

if the slot is empty:

a. Disconnect any external cables that are attached to the PCI card.

b. Working from the rear of the chassis, pivot the PCI card latch for the slot

upward. See

FIGURE 3-58

.

FT1
FM0

FT1
FM1

FT1
FM2

FT0
FM0

FT0
FM1

FT0
FM2

CPU1

CPU0

Front panel of server

Back panel of server

PCIX1
(133 MHz)

PCIX0
(100 MHz)