2 replacing a cpu and heatsink, Replacing a cpu and heatsink – Sun Microsystems Sun Fire X4100 User Manual

Page 140

Advertising
background image

4-10

Sun Fire X4100 and Sun Fire X4200 Servers Service Manual • June 2006

4.4.2

Replacing a CPU and Heatsink

Follow these steps to remove and replace the a CPU and its heatsink.

Note –

This component is a FRU and should be replaced only by qualified service

technicians. Contact your Sun Service representative for assistance.

TABLE 4-2

lists the qualified part numbers for this component. These part numbers

are subject to change over time. For the most up-to-date list of replaceable
components, product updates, and downloads, see the following URL:

http://www.sun.com/servers/entry/x4100/downloads.jsp

Caution –

Some AMD CPUs are released as Special Editions, which might differ in

wattage from non-Special Edition versions of the CPU. Do not mix Special Edition
CPUs with non-Special Edition versions. Always make sure that all CPUs in the
server have the same part number.

1. Power off the server as described in

Section 4.2.1, “Powering Off the Server” on

page 4-2

.

2. If the server is in a rack, slide it far enough from the rack so that you can remove

the main cover. If you cannot safely view and access the component, remove the
server from the rack.

3. Remove the main cover as described in

Section 4.2.2, “Removing the Main Cover”

on page 4-3

.

TABLE 4-2

Sun Fire X4200 Supported CPU Part Numbers

Component

Part Number

AMD 248 (2.2 GHZ) Opteron single-core CPU

370-7711

AMD 252 (2.6 GHZ) Opteron single-core CPU

370-7272

AMD 254 (2.8 GHZ) Opteron single-core CPU

370-7962

AMD 256 (3.0 GHz) Opteron single-core CPU

371-1776

AMD 270 (2.0 GHZ) Opteron dual-core CPU

370-7799

AMD 275 (2.2 GHZ) Opteron dual-core CPU

370-7800

AMD 280 (2.4 GHz) Opteron dual-core CPU
* See the caution after this table.

370-7938

AMD 285 (2.6 GHz) Opteron dual-core CPU
* See the caution after this table.

371-0856