Chapter 4

Maintaining the Sun Fire X4200 Server

4-17

4.4.3

Replacing the DVD-ROM Drive

Follow these steps to remove and replace the DVD-ROM drive.

If you are installing a DVD-ROM upgrade kit to a system that previously did not
have a DVD-ROM drive, see

Section 4.4.4, “Installing a DVD-ROM Drive

Upgrade Kit” on page 4-20

.

Note –

This component is a FRU and should be replaced only by qualified service

technicians. Contact your Sun Service representative for assistance.

TABLE 4-3

lists the qualified part numbers for this component. These part numbers

are subject to change over time. For the most up-to-date list of replaceable
components, product updates, and downloads, see the following URL:

http://www.sun.com/servers/entry/x4100/downloads.jsp

1. Power off the server as described in

Section 4.2.1, “Powering Off the Server” on

page 4-2

.

2. If the server is in a rack, slide it far enough from the rack so that you can remove

the main cover and front cover. If you cannot safely view and access the
component, remove the server from the rack.

3. Remove the main cover as described in

Section 4.2.2, “Removing the Main Cover”

on page 4-3

.

4. Remove the front bezel as described in

Section 4.2.3, “Removing the Front Bezel”

on page 4-4

.

Note –

Always unfasten the bezel’s securing screw before removing the bezel.

5. Remove the front cover as described in

Section 4.2.4, “Removing the Front Cover”

on page 4-5

.

6. Remove the upper cable retainer from the chassis midwall. See

FIGURE 4-13

.

TABLE 4-3

Sun Fire X4200 Supported DVD-ROM Drive Part Numbers

Component

Part Number

Slim-slot DVD-ROM drive
(RoHS-compliant, replaces 540-6368)

390-0320