6 replacing a fan connector board, Replacing a fan connector board – Sun Microsystems Sun Fire X4100 User Manual

Page 157

Advertising
background image

Chapter 4

Maintaining the Sun Fire X4200 Server

4-27

4.4.6

Replacing a Fan Connector Board

Follow these steps to remove and replace a fan connector board.

Note –

This component is a CRU and can be replaced by anyone.

TABLE 4-6

lists the qualified part numbers for this component. These part numbers

are subject to change over time. For the most up-to-date list of replaceable
components, product updates, and downloads, see the following URL:

http://www.sun.com/servers/entry/x4100/downloads.jsp

1. Power off the server as described in

Section 4.2.1, “Powering Off the Server” on

page 4-2

.

2. If the server is in a rack, slide it far enough from the rack so that you can open the

fan bay door. If you cannot safely view and access the component, remove the
server from the rack.

Caution –

When you open the fan bay door, be careful to hold it open with one

hand so that it does not spring shut and injure your fingers. Do not hold the fan bay
door open for more than 60 seconds while the server is running to avoid overheating
the server.

3. Open the fan bay door and hold it open. See

FIGURE 4-22

.

TABLE 4-6

Sun Fire X4200 Supported Fan Connector Board Part Numbers

Component

Part Number

Fan connector board

501-6917