Sun Microsystems Sun Fire X4100 User Manual

Page 189

Advertising
background image

Chapter 4

Maintaining the Sun Fire X4200 Server

4-59

13. Remove the flex cable and its attached foam rubber gasket from the chassis inner

wall by disconnecting the cable’s four connectors from the following four
locations. See

FIGURE 4-55

.

1. DVD-ROM drive

2. Hard disk drive backplane

3. Power distribution board

4. Motherboard

Note –

When reinstalling the flex cable, attach the connector to the power

distribution board (3) first. Then attach the remaining three connectors in any order.

FIGURE 4-55

Disconnecting the Flex Cable’s Four Connectors

14. Unfasten and remove the eight screws that secure the motherboard to the chassis

floor. See

FIGURE 4-56

for the location of the eight screws.

15. Use an 8mm nut-driver to remove the two bus-bar nuts from the motherboard. See

FIGURE 4-56

.

Note –

If you remove the HDDs from the server for any reason during this

procedure, you must return each HDD to the bay from which it was removed. Use
an adhesive note or another method to temporarily label the HDDs after you remove
them.