Sun Fire X4100 and Sun Fire X4200 Servers Service Manual • June 2006

11. Replace the front bezel to the chassis:

a. Align the pegs on the rear of the bezel with the corresponding holes in the

front of the chassis.

Note –

Ensure that the new DVD-slot faceplate is over the DVD-ROM drive and

that the button on the DVD-slot faceplate is oriented toward the chassis bottom. See

FIGURE 4-1

.

b. Press the bezel evenly against the front of the chassis until it is flat against the

front of the chassis.

c. Open the fan bay door on the front cover and tighten the captive retaining

screw that secures the bezel in place. See

FIGURE 4-3

.

12. Replace the main cover to the chassis:

a. Set the cover in place so that it aligns with the keyed openings in the chassis

sides.

b. Slide the cover toward the chassis front until it is firmly and squarely against

the edge of the front cover.

13. Return power to the server. See

Section 2.1, “Powering On the Server” on page 2-2

.