Sun Microsystems Sun Fire X4100 User Manual

Page 71

Advertising
background image

Chapter 3

Maintaining the Sun Fire X4100 Server

3-11

4. Identify which CPU and heatsink you are replacing.

The internal system software designation of the two CPUs in the server is shown in

FIGURE 3-7

. There is a fault LED on the motherboard for each CPU (see

FIGURE 3-8

for

the LED location):

LED is off: CPU is OK.

LED is lit (amber): CPU has encountered a voltage or heat error condition.

FIGURE 3-7

Sun Fire X4100 Designation of CPUs

5. Remove the CPU and heatsink from the motherboard:

a. Hold down on the top of the heatsink to prevent it from tipping unevenly

while you alternately loosen the two spring-loaded mounting screws that
secure the heatsink to the motherboard. Turn the screws 180-degrees at a time,
then remove the screws when they are detached. See

FIGURE 3-8

and

FIGURE 3-9

.

FT1
FM0

FT1
FM1

FT1
FM2

FT0
FM0

FT0
FM1

FT0
FM2

CPU1

CPU0

DIMM 0

DIMM 2

DIMM 1

DIMM 3

DIMM 0

DIMM 2

DIMM 1

DIMM 3

Front panel of server

Back panel of server

CPU 1:

CPU 0: