13 replacing the motherboard, Replacing the motherboard – Sun Microsystems Sun Fire X4100 User Manual

Page 182

Advertising
background image

4-52

Sun Fire X4100 and Sun Fire X4200 Servers Service Manual • June 2006

4.4.13

Replacing the Motherboard

Follow these steps to remove and replace the motherboard.

Note –

This component is a FRU and should be replaced only by qualified service

technicians. Contact your Sun Service representative for assistance.

TABLE 4-14

lists the qualified part numbers for this component. These part numbers

are subject to change over time. For the most up-to-date list of replaceable
components, product updates, and downloads, see the following URL:

http://www.sun.com/servers/entry/x4100/downloads.jsp

1. Power off the server as described in

Section 4.2.1, “Powering Off the Server” on

page 4-2

.

2. If the server is in a rack, remove the server from the rack.

3. Remove the main cover as described in

Section 4.2.2, “Removing the Main Cover”

on page 4-3

.

4. Remove the front bezel as described in

Section 4.2.3, “Removing the Front Bezel”

on page 4-4

.

Note –

Always unfasten the bezel’s securing screw before removing the bezel.

5. Remove the front cover as described in

Section 4.2.4, “Removing the Front Cover”

on page 4-5

.

6. Remove all PCI cards:

a. Disconnect any external cables from the PCI cards.

b. Working from the rear of the chassis, pivot each card latch to release the rear of

the PCI cards. See

FIGURE 4-45

.

TABLE 4-14

Sun Fire X4200 Supported Motherboard Part Numbers

Component

Part Number

Motherboard, Sun Fire X4200
(RoHS-compliant, replaces 501-6974 and 501-7645)

501-7514