Primera Technology Fujitsu Tape Drive RX300 S2 User Manual

Page 205

Advertising
background image

205

PRIMERGY RX300 S2 User’s Guide

Inst
allin
g I

nte

rn

al O

pti

ons

7

■ Replacing the Failed Internal Hard Disk Unit

When an array system (RAID1/5/10) is configured with the onboard SCSI array controller on this

server, a failed hard disk unit can be replaced and restoration can be performed without turning off the

server and peripheral devices (hot swappable/hot pluggable). For details on the array system, refer to

"Onboard SCSI RAID User's Guide".

The following is an outline of the procedure for replacing a failed internal hard disk unit.

1

Check the hard disk unit failure LED on each bay.

2

Touch a metal part of the server to discharge static electricity.

3

Move the handle on the failed hard disk unit up and pull it towards you.

4

Wait for approximately 60 seconds (until the hard disk stops rotating) and pull

out the failed hard disk unit.

5

Install a new internal hard disk unit.

6

Rebuild the new hard disk unit.

"Rebuild" may be executed automatically after hard disk unit was replaced. You can confirm the

state of the hard disk unit by checking the hard disk failure LED.

Advertising