Chapter 8 Hardware Configuration/Utilities

8.2.10 IPMI Submenu

Appears when [IPMI] is selected from the [Advanced] menu.

Configures the Baseboard Management Controller (BMC).

Wake Up Time

-

Configures the power-on time setting using the
timer.

Wake Up Mode

-

Specifies the power-on interval using the timer.

Power Failure Recovery

• Always Off
• Always On
• Previous State (at the

time of purchase)

Sets the server power status after system down due
to power failure or after power recovery by the
UPS.

Note:

Set this item to [Always ON] when a UPS is

used.

table: Items on the IPMI Submenu

Item

Setting

Description

SEL Load

-

Displays the stored SEL in percentage.

Clear System Event Log

• Disabled (at the time of

purchase)

• Enabled

Deletes logs stored in System Event Log (SEL).
(Do not delete SEL from this menu.)

Event Log Full Mode

• Overwrite (at the time of

purchase)

• Maintain

Configures the log when full SEL is indicated.

BMC Time Sync

Enabled (Fixed parameter)

Sets whether or not to synchronize the BMC
internal timer with RTC at startup.

table: Items on the Power On/Off Submenu

Item

Setting

Description

Item Specific Help

F1

Esc

Select Item

Select Menu

Change Values

Select Sub-Menu

-/+

Enter

Info

Exit

F9

F7

Setup Defaults

Previous Values

PhoenixBIOS Setup Utility

Advanced

SEL Load nn%
Clear System Event Log [Disabled]
Event Log Full Mode: [Overwrite]
BMC Time Sync: [Enabled]
System Event Log
SDRR Browser
LAN Settings

IPMI

Advertising