Primera Technology Fujitsu Tape Drive RX300 S2 User Manual

Page 264

Advertising
background image

264

Chapter 9 Operation and Maintenance

ERROR:Fail to create data file.

The following are possible causes. Check the floppy
disk status again.

• The floppy disk is write-protected. Disable the

write-protect and retry.

• The floppy disk is not inserted into the floppy disk

drive. Insert the proper floppy disk, and then retry.

• The floppy disk contains abnormal contents. Create

the "Server Management Tools" floppy disk again. If
this occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.

ERROR:Fail to write 1st CMOS data into data file. nn

ERROR:Fail to write 2nd CMOS data into data file. nn

ERROR:Fail to write ESCD data into the data file. nn

ERROR:Fail to write SEEPROM data into the data file.
nn

ERROR:Fail to open data file.

The file for recovering the BIOS information does not
exist on this floppy disk. Insert the floppy disk on
which the BIOS information was stored, and then retry.

ERROR:Fail to write 1st CMOS data into system. nn

The following are possible causes. Check the floppy
disk status again.

• The floppy disk is not inserted into the floppy disk

drive. Insert the proper floppy disk, and then retry.

• A different model or an unsupported version of

BIOS information. Insert the proper floppy disk, and
then retry.

• The floppy disk contains abnormal contents. Create

the "Server Management Tools" floppy disk again. If
this occurred while recovering BIOS information,
configure the information using the BIOS Setup
Utility. Then store the BIOS information.

ERROR:Fail to write 2nd CMOS data into system file.
nn

ERROR:Fail to write ESCD data into system file. nn

ERROR:Fail to write SEEPROM data into system. nn