B.5 power cord selection, For the united states and canada – Primera Technology Fujitsu Tape Drive RX300 S2 User Manual

Page 297

Advertising
background image

297

PRIMERGY RX300 S2 User’s Guide

Ap
pend

ix

A

B.5

Power Cord Selection

The power cord for this unit has been packed separately and has been selected according to the country

of destination. It must be used to prevent electric shock. Use the following guidelines if it is necessary to

replace the original cord set.

The female receptacle of the cord set must meet CEE-22 requirements (see Figure).

■ For the United States and Canada

Use a UL listed and CSA labeled cord set consisting of a three conductor cord with a maximum length

of 15 feet.

For units which stand on a desk or table, type SVT or SJT cord sets should be used.

For units which stand on the floor, only SJT type cord sets should be used.

The cord set must be selected according to the current rating for your unit.

Please consult the table below for the selection criteria for power cords used in the United States and

Canada.

For units set at 230 V (outside of the United States and Canada):

Use a cord set consisting of a minimum AWG according to the table above and a grounding type

attachment plug rated 15 A, 250 V. The cord set should have the appropriate safety approvals for the

country in which the equipment will be installed and should be marked HAR.

table: Selection Criteria for Power Cords Used in the United States and Canada

Cord Type

Size of Conductors in Cord

Maximum Current Rating of Unit

SJT

18 AWG
16 AWG
14 AWG

10 Amps
12 Amps
12 Amps

SVT

18 AWG
17 AWG

10 Amps
12 Amps

• Parallel

For units set at 115 V:

use a parallel blade, grounding type

attachment plug rated 15 A, 125 V.

• Tandem

For units set at 230 V:

use a tandem blade, grounding type

attachment plug rated 15 A, 250 V.