Chapter 2 Checking before OS Installation

2.3.2 Notes on Configuring RAID

Take the following notes when you configure a RAID system.

■ Hardware Configuration

• Only internal hard disk units can be used.

• Be sure to use hard disk units of the same model and with the same capacity.

• Up to six hard disk units can be installed. Do not set the number of units more than the maximum.

• The number of units that can be set at each RAID level is as follows.

• RAID level 0: 2 to 6 units

• RAID level 1: 2 units

• RAID level 5 (recommended): 3 to 6 units

• RAID level 10: 4 or 6 units

When the OS is installed using ServerStart, only one RAID card can be installed. If you need more

cards, install them after OS installation.

■ Array Configuration

The following shows the pack order of hard disk units for a two-channel array configuration by

ServerStart.

For more details on the array configuration, refer to "PRIMERGY RX300 S2 Onboard SCSI RAID

User's Guide".

table: Array Configuration

Item

Contents

Number of physical packs

1

Number of system drives

1

Pack order of hard disk units

Channel 0 is packed preferentially in ascending order of SCSI-ID
set for the hard disk units.

E.g.:(In a two-channel configuration)

Pack A-1 Channel 0 SCSI-ID 0

Pack A-2 Channel 0 SCSI-ID 1

Pack A-3 Channel 0 SCSI-ID 2

Pack A-4 Channel 1 SCSI-ID 0

Pack A-5 Channel 1 SCSI-ID 1

When a hot spare is specified, the hard disk unit with the largest
channel number and the largest SCSI-ID will be used as the hot
spare hard disk unit.