Chapter 9 Operation and Maintenance

9.2.2 Error Messages

This section explains the error messages for this server.

■ POST Error Messages

When an error occurs during POST (Power On Self Test: a device check performed during the server

startup process) on this server, take the corresponding corrective actions described in the table below.

table: List of POST error messages

Message

Description

Failure Fixed Disk 0

From the BIOS Setup Utility, check the [IDE Drive1 - 4] setting
of "8.2.2 Main Menu" ( pg.226) or the [Local Bus IDE
adapter] setting of the [Advanced] menu -"8.2.6 Peripheral
Configuration Submenu" ( pg.231).
If the message still
appears, contact an office listed in the "Contact Information" of
the "Start Guide".

Failure Fixed Disk 1

Fixed Disk Controller Failure

Keyboard controller error

The keyboard is abnormal. Replace the keyboard or mouse. If
the message still appears, the baseboard must be replaced.
Contact an office listed in the "Contact Information" of the
"Start Guide".

Keyboard error

Check to see whether the keyboard is connected properly. If the
message still appears, the keyboard must be replaced.

Keyboard error nn

Remove objects, if any, that are pressing against any keys on the
keyboard. ("nn" is a hexadecimal code representing the key.)
Check to see whether the keyboard is connected properly. If the
message still appears, the keyboard must be replaced.

Stuck Key nn

Keyboard locked - Unlock key switch

Check to see whether the keyboard is connected properly. If the
message still appears, the keyboard must be replaced.

Monitor type does not match CMOS - Run
Setup

An invalid monitor type is set.
Contact an office listed in the "Contact Information" of the
"Start Guide".

Critical memory error occurred - system
halted

The memory is abnormal. Stop the server once, then restart it. If
the message still appears, check the error log and replace the
faulty memory.

Extended RAM Failed at offset: nnnn

System RAM Failed at offset: nnnn

Shadow RAM Failed at offset: nnnn

Memory type mixing detected

The installation configuration of the memory is wrong. Verify
that the same type of memory is installed to the slots of the same
bank. If the memory is properly installed, it needs to be
replaced.

Hot Spare Memory Feature could not be
enabled

The hot spare memory function cannot be enabled. Check that
all the memory modules that are installed are all of the same
capacity. If the message still appears even though the
installation is correct, the memory or baseboard must be
replaced. Contact an office listed in the "Contact Information"
of the "Start Guide".

Correctable memory error in module x

The memory is abnormal. Replace the memory module that
corresponds to "module n" (where n is the slot number).

Uncorrectable memory error in module x

Memory decreased in Size

Power off the server and turn it back on. If the message still
appears, check the error log and replace the faulty memory.