CHAPTER 7 CLOCK GENERATOR

Write to OSMS

(MCS

0)

f

XX

Max. 2/f

X

Operating at f

XX

= f

X

/2 (MCS = 0)

Operating at f

XX

= f

X

/2 (MCS = 0)

MCS

Main System Clock Scaler Control

0

1

Scaler used

Scaler not used

0

0

0

0

OSMS

FFF2H

7

6

5

4

3

2

Symbol

1

0

MCS

0

0

Address

After

Reset

R/W

00H

W

0

(2) Oscillation mode selection register (OSMS)

This register specifies whether the clock output from the main system clock oscillator without passing through

the scaler is used as the main system clock, or the clock output via the scaler is used as the main system

clock.

OSMS is set with 8-bit memory manipulation instruction.

RESET input sets OSMS to 00H.

Figure 7-4. Oscillation Mode Selection Register Format

Cautions 1. The main system clock cycle is longer by up to 2/fx only when writing data to OSMS (including

when writing the same data that was written previously) as shown in Figure 7-5. This causes

a temporary error in the count clock cycle of timers in the peripheral hardware that operates

with the main system clock.

In addition, when the oscillation mode is changed, the clocks provided for the peripheral

hardware as well as those for the CPU are switched. Therefore, it is recommended that only

one-time writing to OSMS be performed between the reset release and the peripheral

hardware operation.

Figure 7-5. Main System Clock when Writing to OSMS

2. Setting 1 to MCS should be performed after V

DD

2.7 V.

Remarks f

xx

: Main system clock frequency (fx or fx/2)

f

x

: Main system clock oscillation frequency