CHAPTER 21 INTERRUPT AND TEST FUNCTIONS

Figure 21-14. Interrupt Request Acknowledge Timing (Minimum Time)

Remark

1 clock :

(f

CPU

: CPU clock)

Figure 21-15. Interrupt Request Acknowledge Timing (Maximum Time)

f

CPU

1

Instruction

Divide Instruction

PSW and PC Save,
Jump to Interrupt
Servicing

6 Clocks

Interrupt
Servicing
Program

33 Clocks

32 Clocks

CPU Processing

Ч Ч

IF

(

Ч Ч

PR=1)

Ч Ч

IF

(

Ч Ч

PR=0)

25 Clocks

f

CPU

1

Remark

1 clock :

(f

CPU

: CPU clock)

Instruction

Instruction

PSW and PC Save,
Jump to Interrupt
Servicing

6 Clocks

Interrupt
Servicing
Program

8 Clocks

7 Clocks

CPU Processing

Ч Ч

IF

(

Ч Ч

PR=1)

Ч Ч

IF

(

Ч Ч

PR=0)