5 16-bit timer/event counter operations, 1 interval timer operations – NEC uPD78056Y User Manual

Page 191

Advertising
background image

191

CHAPTER 8 16-BIT TIMER/EVENT COUNTER

0

0

0

0

0

0/1

0/1

0

CRC02 CRC01 CRC00

CRC0

CR00 set as compare register

8.5 16-Bit Timer/Event Counter Operations

8.5.1 Interval timer operations

Setting the 16-bit timer mode control register (TMC0) and capture/compare control register 0 (CRC0) as shown

in Figure 8-10 allows operation as an interval timer. Interrupt requests are generated repeatedly using the count value

set in 16-bit capture/compare register 00 (CR00) beforehand as the interval.

When the count value of the 16-bit timer register (TM0) matches the value set to CR00, counting continues with

the TM0 value cleared to 0 and the interrupt request signal (INTTM00) is generated.

Count clock of the 16-bit timer/event counter can be selected with bits 4 to 6 (TCL04 to TCL06) of the timer clock

select register 0 (TCL0).

For the operation when the value of the compare register is changed during the timer count operation, refer to

8.6 16-Bit Timer/Event Counter Precautions (3).

Figure 8-10. Control Register Settings for Interval Timer Operation

(a) 16-bit timer mode control register (TMC0)

(b) Capture/compare control register 0 (CRC0)

Remark 0/1 : Setting 0 or 1 allows another function to be used simultaneously with the interval timer. See

the description of the respective control registers for details.

0

0

0

0

1

1

0/1

0

TMC03 TMC02 TMC01 OVF0

TMC0

Clear & start on match TM0 and CR00