NEC uPD78056Y User Manual

Page 297

Advertising
background image

297

CHAPTER 16 SERIAL INTERFACE CHANNEL 0 (

µ

PD78054 Subseries)

Figure 16-4. Serial Operating Mode Register 0 Format (2/2)

Notes 1. To use the wake-up function (WUP = 1), clear the bit 5 (SIC) of the interrupt timing specify register

(SINT) to 0.

2. When CSIE0 = 0, COI becomes 0.

3. In the SBI mode, clear WUP to 0 before stopping (CSIE

0) the operation of serial interface channel

0, otherwise, P25 is fixed to high level and may not be able to be used as a normal port.

WUP

0

1

Wake-up Function Control

Note 1

Interrupt request signal generation with each serial transfer in any mode

Interrupt request signal generation when the address received after bus release (when CMDD = RELD = 1)
matches the slave address register (SVA) data in SBI mode

R/W

COI

0

1

Slave Address Comparison Result Flag

Note 2

Slave address register (SVA) not equal to serial I/O shift register 0 (SIO0) data

Slave address register (SVA) equal to serial I/O shift register 0 (SIO0) data

R

CSIE0

0

1

Serial Interface Channel 0 Operation Control

Note 3

Operation stopped

Operation enable

R/W