CHAPTER 9 8-BIT TIMER/EVENT COUNTERS 1 AND 2

(2) 8-bit compare register 10 and 20 setting

The 8-bit compare registers 10 and 20 (CR10 and CR20) can be set to 00H.

Thus, when these 8-bit compare registers are used as event counters, one-pulse count operation can be

carried out.

When the 8-bit compare register is used as 16-bit timer/event counter, write data to CR10 and CR20 after

setting bit 0 (TCE1) of the 8-bit timer mode control register 1 to 0 and stopping timer operation.

Figure 9-15. Event Counter Operation Timing

(3) Operation after compare register change during timer count operation

If the values after the 8-bit compare registers 10 and 20 (CR10 and CR20) are changed are smaller than those

of 8-bit timer registers (TM1 and TM2), TM1 and TM2 continue counting, overflow and then restart counting

from 0. Thus, if the value (M) after CR10 and CR20 change is smaller than value (N) before the change, it

is necessary to restart the timer after changing CR10 and CR20.

Figure 9-16. Timing after Compare Register Change during Timer Count Operation

Remark

N > X > M

TI1, TI2, Input

CR10, CR20

TM1, TM2 Count Value

TO1, TO2

Interrupt Request Flag

00H

00H

00H

00H

00H

Count Pulse

CR10, CR20

TM1, TM2 Count Value

X-1

X

FFH

00H

01H

02H

M

N